Quest for an Ideal Intubating Device  
     
  Goneppanavar Umesh  
  DOI 10.5001/omj.2012.38  
 
 
 
Associate Professor, Department of Anesthesiology, Kasturba Medical College, Manipal University, Karnataka State, India.

Received: 24 Dec 2011
Accepted: 18 Feb 2012
 
Address correspondence and reprints request to: Goneppanavar Umesh, Associate Professor, Department of Anesthesiology, Kasturba Medical College, Manipal University, Karnataka State, India.
E-mail: drumeshg@yahoo.co.in
 
 
 
 

How to cite this article

Umesh G. Quest for an Ideal Intubating Device. Oman Med J 2012 Mar; 27(2):175-176.

How to cite this URL

Umesh G. Quest for an Ideal Intubating Device. Oman Med J 2012 Mar; 27(2):175-176. Available from http://www.omjournal.org/fultext_PDF.aspx?DetailsID=224&type=fultext

 
 


The first scientific report of tracheal intubation and artificial respiration is attributed to Vesalius, who in 1543 performed this in animals.1 The first perioperative use of tracheal intubation was described by Macewen in 1880 to prevent aspiration during the removal of a tumor from the base of the tongue. However, regular perioperative use of tracheal intubation in anesthetized patients started only in the early 1900s.2 Until then, even oral surgery was performed without a definitive airway, thus predisposing patients to the risk of aspiration. As the use of tracheal tubes and intubation gained popularity, a proportional need to develop equipment that could help in placing a tracheal tube into the trachea arose. In 1913, Chevalier Jackson reported a high rate of success for the use of direct laryngoscopy as a means to intubate the trachea.3

The development of a rigid, curved laryngoscope by Macintosh in 1943, made the process of intubation simpler and less traumatic as it could now be performed under direct vision. Development of anesthetic drugs that rendered the patient unconscious within seconds and muscle relaxants that facilitated intubation made direct laryngoscopy and intubation the most followed technique for the establishment of a definitive airway.4 However, as the technique gained popularity, its limitations also came to the fore.

A limited mouth opening (<25 mm) or an anteriorly placed glottis were commonly encountered situations where direct laryngoscopy and intubation was rendered difficult if not impossible.5,6 This resulted in the development of several alternatives to facilitate tracheal intubation; such as intubating laryngeal mask airway (ILMA), lightwand, fiberoptic bronchoscope (fiberscope), and video/optical laryngoscopes (such as Airtraq, Glidescope, retromolar scope, bullard laryngoscopeetc).7-16 While some of these devices permit visualization of the larynx prior to intubation; some, such as lightwand /intubating laryngeal mask airway are semi-blind or blind techniques. Despite manifold advances in the development of airway gadgets and a vastrange of available devices, only a few prove useful in patients with limited mouth opening where nasal intubation is required. In my opinion, an ideal intubation device should be versatile enough to aid in securing a definitive airway by both oral and nasal routes, especially in situations that result in failure to intubate with direct laryngoscopy. A plausible exception where even such an ideal intubation device may fail would be in the presence of an infraglottic pathology that prevents the advancement of a tracheal tube beyond the glottis.

Among airway devices that are available for tracheal intubation; only fiberscope and lightwand stand out to be useful in both routes of intubation. Both these devices have been proven to be immensely beneficial in a wide range of difficult airway situations across the globe; although each has its own merits and demerits.8,17 Both techniques necessitate mounting of an appropriate sized tracheal tube over the device prior to the initiation of the intubation process. Both devices have also been found to be useful in overcoming difficult intubation when used along with other airway devices.8,18,19

A fibreoptic guided intubation involves visualization of the glottic structures, passage of the fiberscope into the trachea and then railroading the tracheal tube into the trachea over the fiberscope. In addition, it allows oxygen insufflation during intubation attempts. While the flexible nature of the fiberscope makes it a handy and useful device for securing the airway in patients with intraoral pathology such as tumors or distorted anatomy of the larynx; the distorted anatomy itself may result in failure to railroad a tracheal tube despite having the fiberscope inthe trachea.8 Further, fiberscopes are expensive, fragile, demand meticulous maintenance and sterilization, and can still be rendered useless in the presence of blood or secretions.20

A lightwand on the other hand, relies on a semi-blind technique that uses the principle of trans-illumination of the soft tissues of the anterior neck to guide the tip of the tracheal tube into the trachea. The superficial location of the trachea in relation to the oesophagus is taken advantage of by this technique.21 In view of the semi-blind nature of this technique, lightwand guided intubation is not affected by the presence of blood or secretions in the oral cavity. The semi-rigid nature of the lightwand stylet enhances chances for successful advancement of the tracheal tube into the glottis. However, being a semi-blind technique, it is unsuitable for use in patients with altered laryngeal anatomy or intraoral tumors.22 Also, the necessity to locate a "well circumscribed glow" in the mid-neck as a marker for identification of the trachea makes it less useful in patients with a thick neck or a mass in the midneck.23

In my experience, I have found the flexible fiberscope and the lightwand to be the most versatile of all airway gadgets meant for endotracheal intubation when direct laryngoscopy and intubation is either a failure or not an option. Both these devices are known to have a relatively long learning curve. However, once mastered, like swimming or cycling; the art cannot be forgotten. If a lightwand could be incorporated with an optical visualization stylet, the inherent drawbacks related to this technique may be overcome, making it the ideal intubating device.

Despite these advantages, the quest for an ideal intubation device will continue. Supraglottic devices such as laryngeal mask airway and equipment suitable for emergency infraglottic access will persist to play an important role in difficult airway situations and should be readily available. However, more important than developing an ideal intubation device, would be to develop oneself into an "ideal intubator" capable of handling any difficult airway scenario through repeated practice and proficiency with a range of available airway devices.

It is always better to be prepared for an eventuality and not have onethan… vice versa.

Acknowledgements

The authors reported no conflict of interest and no funding wa sreceived for this work.


References

1. Ezri T, Evron S, Hadad H, Roth Y. Tracheostomy and endotracheal intubation: a short history. Harefuah 2005 Dec;144(12):891-893, 908.

2. Luckhaupt H, Brusis T. History of intubation. Laryngol Rhinol Otol (Stuttg) 1986 Sep;65(9):506-510.

3. Jackson C. The technique of insertion of intratracheal insufflation tubes. Ped Anesth 1996;6:230.

4. Di Marco P, Scattoni L, Spinoglio A, Luzi M, Canneti A, Pietropaoli P, et al. Learning curves of the Airtraq and the Macintosh laryngoscopes for tracheal intubation by novice laryngoscopists: a clinical study. Anesth Analg 2011 Jan;112(1):122-125.

5. Berkow LC. Strategies for airway management. Best Pract Res Clin Anaesthesiol 2004 Dec;18(4):531-548.

6. Aiello G, Metcalf I. Anaesthetic implications of temporomandibular joint disease. Can J Anaesth 1992 Jul;39(6):610-616.

7. Hung O, Law JA. Advances in airway management. Can J Anaesth 2006 Jun;53(6):628-631.

8. Asai T, Shingu K. Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: incidence, causes and solutions. Br J Anaesth 2004 Jun;92(6):870-881.

9. Umesh G, Manjunath P, Kini G, Jasvinder K. A technique to overcome inability to advance a tracheal tube over a fiberscope during nasotracheal intubation. J Anesth 2010 Oct;24(5):819-820.

10. Trimmel H, Kreutziger J, Fertsak G, Fitzka R, Dittrich M, Voelckel WG. Use of the Airtraq laryngoscope for emergency intubation in the prehospital setting: a randomized control trial. Crit Care Med 2011 Mar;39(3):489-493.

11. Benjamin FJ, Boon D, French RA. An evaluation of the GlideScope, a new video laryngoscope for difficult airways: a manikin study. Eur J Anaesthesiol 2006 Jun;23(6):517-521.

12. Zamora JE, Nolan RL, Sharan S, Day AG. Evaluation of the Bullard, GlideScope, Viewmax, and Macintosh laryngoscopes using a cadaver model to simulate the difficult airway. J Clin Anesth 2011 Feb;23(1):27-34.

13. Abramson SI, Holmes AA, Hagberg CA. Awake insertion of the Bonfils Retromolar Intubation Fiberscope in five patients with anticipated difficult airways. Anesth Analg 2008 Apr;106(4):1215-1217.

14. Komatsu R, Nagata O, Kamata K, Yamagata K, Sessler DI, Ozaki M. Intubating laryngeal mask airway allows tracheal intubation when the cervical spine is immobilized by a rigid collar. Br J Anaesth 2004 Nov;93(5):655-659.

15. Steel A. The intubating laryngeal mask airway. Emerg Med J 2005 Jan;22(1):47-49.

16. Liem EB, Bjoraker DG, Gravenstein D. New options for airway management: intubating fibreoptic stylets. Br J Anaesth 2003 Sep;91(3):408-418.

17. Xue FS, He N, Liao X, Xu XZ, Xu YC, Yang QY, et al. Clinical assessment of awake endotracheal intubation using the lightwand technique alone in patients with difficult airways. Chin Med J (Engl) 2009 Feb;122(4):408-415.

18. Biehl JW, Bourke DL. Use of the lighted stylet to aid direct laryngoscopy. Anesthesiology 1997 Apr;86(4):1012.

19. Chan PL, Lee TW, Lam KK, Chan WS. Intubation through intubating laryngeal mask with and without a lightwand: a randomized comparison. Anaesth Intensive Care 2001 Jun;29(3):255-259.

20. Popat M. Fibreoptic endoscopy equipment. In Popat M, ed. Practical fibreoptic intubation. 1st Ed., Oxford: Butterworth Heinemann, 2001.

21. Umesh G, George M, Venkateswaran R. Tongue traction is as effective as jaw lift maneuver for Trachlight-guided orotracheal intubation. Acta Anaesthesiol Taiwan 2010 Sep;48(3):130-135.

22. Agrò F, Hung OR, Cataldo R, Carassiti M, Gherardi S. Lightwand intubation using the Trachlight: a brief review of current knowledge. Can JAnaesth 2001 Jun;48(6):592-599.

23. Umesh G, Mathew G, Ramkumar V. Trachlight - More practical solutions to commonly encountered problems. Can J Anaesth 2007 May;54(5):398-399.